Investigation of polymer composite material samples by X-ray computed tomography and processing of tomograms with the image of the volume fraction of porosity

Demidov A.A., Krupnina O.A., Mikhailova N.A., Kosarina E.I.
Demidov A.A., Krupnina O.A., Mikhailova N.A., Kosarina E.I. Investigation of polymer composite material samples by X-ray computed tomography and processing of tomograms with the image of the volume fraction of porosity // Proceedings of VIAM. 2021. No. 5. DOI: 10.18577/2307-6046-2021-0-5-105-113. URL: https://test.viam.ru/en/journal/2021/5/11
Keywords
polymer composite material (PCM), x-ray computed tomography (x-ray CT), porosity volume fraction (PVF), segmentation.
Abstract

The question of the quality of samples made of polymer composite materials and its verification by x-ray computed tomography is considered. The capabilities of North Star Imaging X5000 tomograph were studied and the samples from PCM were examined for detection and evaluation of the porosity volume fraction. The factors influencing the accuracy of the estimation of the porosity volume fraction are investigated. Namely the size voxel, a filter material, quantity of projections. On the other hand, the size вокселя defines resolution of the digital image, the relation depends on a material of the applied filter a signal/noise, productivity of control worsens with growth of quantity of projections. The choice of optimum values of the listed parametres is necessary for satisfactory quality received tomographic images.

Reference list
  1. Kablov E.N. New generation materials and digital technologies for their processing. Vestnik Rossiyskoy akademii nauk, 2020, vol. 90, no. 4, pp. 331–334.
  2. Ivanova D.A., Sitnikova A.I., Shlyapina S.D. Composite materials: textbook. Moscow: Yurayt, 2019, p. 13–15.
  3. Kablov E.N., Sagomonova V.A., Sorokin A.E., Tselikin V.V., Gulyaev A.I. Investigation of the structure and properties of a polymer composite material with an integrated vibration-absorbing layer. Vse materialy. Entsiklopedicheskiy spravochnik, 2020, no. 3, p. 2–9.
  4. Kablov E.N., Startsev V.O. Systematical analysis of the climatics influence on mechanical properties of the polymer composite materials based on domestic and foreign sources (review). Aviacionnye materialy i tehnologii, 2018, no. 2 (51), pp. 47–58. DOI: 10.18577/2071-9140-2018-0-2-47-58.
  5. Troitsky V.A., Karmanov M.N., Troitskaya N.V. Non-destructive quality control of composite materials. Tekhnicheskaya diagnostika i nerazrushayushchiy kontrol. 2014, no. 3, p. 20–33.
  6. Vorobe V.V., Markin V.B. Classification of defects in laminated composites. Manufacturing quality control and repair technology for composite structures. Novosibirsk: Nauka, 2006, pp. 20–25.
  7. Kartashova E.D., Muizemnek A.Yu. Technological defects in polymer layered composite materials. Izvestiya vysshikh uchebnykh zavedeniy. Povolzhskiy region. Tekhnicheskiye nauki, 2017, no. 2 (42), pp. 79–89.
  8. Boychuk A.S., Dikov I.A., Generalov A.S. The increase of sensitivity and resolution of FRP solid samples nondestructive ultrasonic testing using the ultrasonic phased array. Aviacionnye materialy i tehnologii, 2019, no. 3 (56), pp. 83–88. DOI: 10.18577/2071-9140-2019-0-3-83-88.
  9. Chertishchev V.Yu. The estimation of the probability of defects detection by the acoustic methods, depending on their size in constructions from PCM for output control data in the form of binary. Aviaсionnye materialy i tehnologii, 2018, no. 3, pp. 65–79. DOI: 10.18577 / 2071-9140-2018-0-3-65-79.
  10. Kruth J.P., Bartscher M. Computed tomography for dimensional metrology. CIRP Annals – Manufacturing Technology, 2011, no. 60, pp. 821–842.
  11. Demidov A.A., Mikhailova N.A., Krupnina O.A. Estimation of the volume fraction of porosity in samples made of polymer composite materials by x-ray computed tomography. Digital technologies, modeling and automation of non-destructive testing processes in the aerospace industry. Problems and prospects of implementation: materials of the XIII All-Russian. conf. on testing and research of properties of materials «TestMat». Moscow: VIAM, 2021, pp. 114–132.
  12. Krupnina O.A., Kosarina E.I., Demidov A.A., Turbin E.M. Choice of modes and parameters of control of aviation equipment by digital radiography method. Kommentarii k standartam, TU, sertifikatam: yezhemesyachnoye prilozheniye k zhurnalu «Vse materialy. Entsiklopedicheskiy spravochnik». 2017, no. 8, pp. 50–51.
  13. Kosarina E.I., Demidov A.A., Mikhaylova N.A., Smirnov A.V. Theoretical aspects when creating elec-tronic reference X-ray images containing quantitative information. Aviacionnye materialy i tehnologii, 2019, no. 4 (57), pp. 87–94. DOI: 10.18577/2071-9140-2019-0-4-87-94.
  14. Simonov E.N., Kuznetsov K.N. Reconstruction of volumetric images of x-ray computed tomography using holographic methods. Vestnik YuUrGU. Ser.: Kompyuternye tekhnologii, upravlenie, radioelektronika, 2013, vol. 13, no. 3, pp. 77–81.
  15. Vinogradova A.A., Kaznacheeva A.O., Musalmov V.M. Fractal analysis of brain tomograms. Izvestiya vuzov. Ser.: Priborostroyenie. 2013, vol. 56, no. 12, pp. 14–19.
  16. Gonzalez R., Woods R. Segmentation (image processing). Digital image processing. 3rd ed., rev. and add. Moscow: Tekhnosfera, 2012, pp. 860–865.
  17. Chulichkov A.I., Pytev Yu.P., Falomkina O.V., Zubyuk A.V. Methods of morphological analysis of data and their applications. Uchenye zapiski fizicheskogo fakulteta moskovskogo universiteta, 2017, no. 4, art. 1740707. Available at: http://uzmu.phys.msu.ru (accessed: March 30, 2021).
  18. Kato M., Takahashi M. Evaluation of porosity and its variation in porous materials using microfocus x-ray computed tomography considering the partial volume effect. Materials Transactions, 2013, no. 9, pp. 1678–1685.